#include <OMX_Audio.h>
Data Fields | |
OMX_U32 | nSize |
OMX_VERSIONTYPE | nVersion |
OMX_U32 | nPortIndex |
OMX_BOOL | bLinear |
OMX_BS32 | sVolume |
Definition at line 964 of file OMX_Audio.h.
size of the structure in bytes
Definition at line 965 of file OMX_Audio.h.
OMX specification version information
Definition at line 966 of file OMX_Audio.h.
Port index indicating which port to set. Select the input port to set just that port's volume. Select the output port to adjust the master volume.
Definition at line 967 of file OMX_Audio.h.
Referenced by main(), omx_audio_mixer_component_GetConfig(), and omx_audio_mixer_component_SetConfig().
Is the volume to be set in linear (0.100) or logarithmic scale (mB)
Definition at line 972 of file OMX_Audio.h.
Referenced by omx_volume_component_GetConfig().
Volume linear setting in the 0..100 range, OR Volume logarithmic setting for this port. The values for volume are in mB (millibels = 1/100 dB) relative to a gain of 1 (e.g. the output is the same as the input level). Values are in mB from nMax (maximum volume) to nMin mB (typically negative). Since the volume is "voltage" and not a "power", it takes a setting of -600 mB to decrease the volume by 1/2. If a component cannot accurately set the volume to the requested value, it must set the volume to the closest value BELOW the requested value. When getting the volume setting, the current actual volume must be returned.
Definition at line 974 of file OMX_Audio.h.
Referenced by main(), omx_audio_mixer_component_GetConfig(), omx_audio_mixer_component_SetConfig(), omx_volume_component_GetConfig(), and omx_volume_component_SetConfig().